Rigid Polyurethane Foam Insulation
Rigid Polyurethane Foam Insulation has superb insulating properties and is used in a variety of applications such as reinforcement of FRP ships,
water tank insulation, freezer containers, building insulation and pipe insulation.

Characteristics of Rigid Polyurethane Foam Insulation

※ Please turn it over to see the contents.
Type Details Characteristics
Insulation Board Type 1 No. 1 Insulation board which does not have an outer layer produced by foam injection molding using polyisocyanates, polyol and blowing agent. high density
No.2 intermediate density
No.3 low density
Type 2 No.1 Insulation board produced by foam injection molding using polyisocyanates, polyol and blowing agent between two sheets of material which forms the outer layer through self-adhesion. high density
No.2 intermediate density
No.3 low density
Insulation Container No.1 Insulation in cylindrical form produced by foam injection molding using polyisocyanates, polyol and blowing agent. high density
No.2 intermediate density
No.3 low density

Insulation for FRP Ships

Types of Insulation for FRP Ships

[Type 1 (block)]
Width×Height : 900×900
Thickness : 20~520T
[Type 2 (board)]
Width×Height : 1000×1000
Thickness : 20T,25T,30T,40T,50T

Packaging Condition of Insulation for FRP Ships

Place of Use : shipyards that manufacture FRP ships

Building Insulation

Types of Building Insulation

[Type 1 - No.1,No.2,No.3]
Width×Height : 1000×2000
Thickness : 20~220T
[Type 2 - No.1,No.2,No.3]
Width×Height : 1000×2000
Thickness : 20~220T

건축용 단열재 사용처

Characteristics of Rigid Polyurethane Foam Insulation

※ Please turn it over to see the contents.
Type Apparent Density ㎏/㎥ Heat Transfer W/m·K Flexural Strength N/㎠ Compressive Strength N/㎠ Absorption Volume g/100㎠ Combustibility
Insulation Board Type 1 No.1 Over45 Under0.024 Over35 Over30 Under3.0 Must have a combustion time of no longer than 120 seconds and combustion spread less than 60mm.
No.2 Over35 Under0.024 Over25 Over20
No.3 Over25 Under0.025 Over15 Over10
Type 2 No.1 Over45 Under0.023 Over35 Over15 -
No.2 Over35 Under0.023 Over25 Over10
No.3 Over25 Under0.024 Over15 Over8
Insulation Container No.1 Over45 Under0.024 Over35 Over30 Must have a combustion time of no longer than 120 seconds and combustion spread less than 60mm.
No.2 Over35 Under0.024 Over25 Over28
No.3 Over25 Under0.025 Over15 Over10

Performance Evaluation Report of Rigid Polyurethane Foam Insulation

[Type 1]
[Type 2]